Menu
产品中心
Home>Proportion Directional Valves>Proportional Solenoid Controlled Pilot Valve Without Position Feedback
Proportional Solenoid  Controlled Pilot Valve Without Position Feedback
Proportional Solenoid  Controlled Pilot Valve Without Position Feedback
Proportional Solenoid  Controlled Pilot Valve Without Position Feedback
Proportional Solenoid  Controlled Pilot Valve Without Position Feedback

Proportional Solenoid Controlled Pilot Valve Without Position Feedback

1. Pilot type control two-stage proportional directional valve, without the main spool displacement electrical feedback, the main spool by the spring; 2. Accurate stepless flow regulation (without pressure compensation) and direction control can be realized; 3. Pilot valve with central thread proportional electromagnet, coil can be separately removed; 4. Electromagnet with optional manual emergency operation; 5. Used for bottom plate installation, installation surface according to the unified international standard ISO 4401; 6. The electric control device is external, which can be used interchangeably with similar products in Europe and America;
Description

4WRZ

E

16

-C2

-125

A

- 10

- D24

- ET

- K31

-A1

-D3

-V

-**

1

  2

3

 4

 5

 6

 7

8

 9

 10

 11

 12

13

 14

1- Pilot type without displacement electrical feedback
2- electronic control blank: external type amplifier plate; E: Integrated amplifier plate
3- Nominal size 10:10 size; 16:16 size; 25:25 path;
4- Slide column function See slide column function table
5- Nominal flow 
      10 diameter 25:25L/min; 50:50L/min; 80:80L/min
      16 diameter 100:100L/min; 150:150L/min
       25 diameter 220:220L/min; 325:325L/min
6- Throttling groove form
7- Design code
8- Power supply voltage blank: none (for 4WRZ); D24:DC24V(for 4WRZE)
9- electromagnet operation blank: no manual emergency operation; N9: Manual emergency operation with guard
10- Control form blank: internal control and internal leakage; E: external control and internal leakage; T: Internal control leakage; ET: External control leakage
11- Electrical connection 4WRZ Blank: with coil plug (PG11); K4: None
4WRZE blank: with amplifier plug; K31: None
12- Control instruction blank: for 4WRZ; A1: command value ±10V; F1: Instruction 4 to 20Ma
13- blank: no fixed pressure reducing valve; D3: With fixed pressure reducing valve
14- Sealing material blank: nitrile rubber; V: Fluorine rubber
15- More details

16:460

Maximum pressure315        bar
Maximum flow

10:170

16:460

25:870

 L/min
Working mediumIn line with DIN51524 standard mineral oil (HL, HLP), other oil please consult our company   /

Recommended viscosity range

20 to 380mm2/s(30 to 46mm2/s is preferred)   /
Oil contamination degree

Pilot control valve: the highest pollution level according to NAS1638 class 7 or ISO4406 class 18/16/13   
Main valve: The highest pollution level is NAS1638 Class 9 or ISO4406 Class 20/18/15

 /